Cargo tank in a bitumen tanker
LevelPoint Level

Overview
Bitumen is transported at temperatures of around 170 °C to 190 °C. The heating is supplied via an array of multi-layered heating tubes mounted on the floor and sides of the tanks. To ensure efficient utilisation of the tanks as well as a safe ship attitude, the levels in the bitumen tanks require accurate monitoring, particularly during loading and unloading.
Operating Conditions
- Measuring Task
- Level measurement and point level detection
- Measuring Point
- Tank
- Medium
- Bitumen
- Measuring Range
- 15 m
- Temperature
- +170 … +190 °C
- Pressure
- 0 … 0 bar
Challenges
- High temperatures, chemically aggressive medium, condensation, highly viscous, heavy buildup, heating pipes at the tank bottom, ship approvals
Benefits
- Reliable: Reliable measurement solution for adhesive media
- Cost effective: Accurate measurement of the tank contents, regardless of medium and degree of contamination
- User friendly: Maintenance-free and reliable operation
Recommended Products
Recommended Sensors

Industrial Sensors
VEGACAP 64
- Reduced number of cleaning cycles through measurement insensitive to buildup
- Long lifetime and low maintenance requirement through robust construction
- Reliable measurement with strong buildup through optimized construction
VEGA
View Details

Industrial Sensors
VEGAPULS 6X
- Exact measuring results independent of process conditions
- Maintenance-free operation through non-contact measuring principle
- Application-oriented configuration enables a simple device selection
VEGA
View Details
Wireless & Connectivity
Need Help With This Use Case?
Our team can help you select the right products.