Drum coater storage tank
LevelPoint Level

Overview
In the pharmaceutical industry, tablets are coated with colouring agents or active ingredients in a drum coater. This coating in the form of a liquid suspension, contains colouring or solids and is stored in a storage tank next to the drum. Itis sprayed into the drum via nozzles for even distribution on the surface of the tablets. Reliable level measurement in the storage tank is required to ensure that there is always enough of the liquid suspension for tablet coating. Overflow and dry run protection is provided by a reliable level switch.
Operating Conditions
- Measuring Task
- Level measurement and point level detection
- Measuring Point
- Tank
- Medium
- Colouring agent or solids-containing suspension
- Measuring Range
- 2 m
- Temperature
- +15 … +25 °C
- Pressure
- 0 ... +1 bar
Challenges
- Low level, buildup
Benefits
- Reliable: Approved materials acc. to FDA and EC 1935/2004
- Cost effective: Continuous coating is ensured thanks to maintenance-free operation
- User friendly: Simple mounting
Recommended Products
Wireless & Connectivity
Need Help With This Use Case?
Our team can help you select the right products.