A hot caustic solution is required for fast cleaning. It is heated in the storage tank and then flushed into the production equipment. The tank is wrapped in a steam heating jacket that serves to control the temperature inside the tank. The level measuring system is used to control filling and discharge. Level detection prevents the tank from overfilling or running empty.

Operating Conditions

Measuring Task
Level and pressure measurement, point level detection
Measuring Point
Tank
Medium
Solvents
Measuring Range
1.4 m
Temperature
-10 … +150 °C
Pressure
-1 … +10 bar

Challenges

  • Condensate, media a with low dielectric constant

Benefits

  • Reliable: Certified materials according to FDA and EC 1935/2004 regulations
  • Cost effective: Maintenance-free operation
  • User friendly: Simple installation