Ultrapure water storage tank
LevelPressure

Overview
High-purity water (WFI) is required for pharmaceutical products that are injected directly into the bloodstream or administered as eye or nose drops. This water is produced through filtration and distillation, then stored temporarily in tanks. Absolute sterility and cleanability are essential criteria for all process components that have direct contact with the medium. This also applies to the instruments for level and pressure measurement in the tank.
Operating Conditions
- Measuring Task
- Level and pressure measurement
- Measuring Point
- Tank and pipeline
- Medium
- water
- Measuring Range
- 5 m
- Temperature
- -40 … +135 °C
- Pressure
- 0 … +5 bar
Challenges
- Hygienic production conditions
Benefits
- Reliable: Certified hygienic design (3A/EHEDG) and approved materials according to EC 1935/2004 and FDA
- Cost effective: Three instruments deliver four different measured values: pressure (head pressure and line pressure), liquid level and temperature
- User friendly: Standardized housing and adjustment concept
Recommended Products
Recommended Sensors

Radar LevelLevel
VEGAPULS 6X
- Exact measuring results independent of process conditions
- Maintenance-free operation through non-contact measuring principle
- Application-oriented configuration enables a simple device selection
VEGA
View Details

HydrostaticLevel
VEGABAR 82
- Low maintenance costs thanks to wear-free ceramic measuring cell
- High plant availability through maximum overload and vacuum resistance of the ceramic measuring cell
- Measurement down to the last drop through smallest measuring ranges with high accuracy
VEGA
View Details
Wireless & Connectivity
Need Help With This Use Case?
Our team can help you select the right products.